Gate opens or closes, then reverses
The gate starts moving, then stops and goes back. The opener thinks it hit something. Sometimes it did.
Common causes
- The gate is binding: a sagging leaf dragging the ground, a dry or worn hinge, or a slide gate with a bad roller or debris in the track. The opener feels the extra load and reverses.
- Force or obstruction settings: set too sensitive for the gate, especially after a season change or new hardware.
- Wind: solid gates catch wind and can trip the obstruction sensing.
- Safety device flickering: photo eyes or edges that cut in and out.
- Weak battery: not enough power to finish the stroke.
What you can check safely
- With the power off and the opener released, move the gate by hand. It should move smoothly through its whole travel without dragging or sticking.
- Look for a sag at the latch end, scrape marks on the drive, or a hinge that’s worn or dry.
- Check the photo eyes for alignment and obstructions.
Safety first. An automatic gate can start moving on its own. Stay out of its path, and turn off the power before you touch the opener, the arm or the control box. Leave board and wiring work to a technician.
When to call a tech
If the gate binds by hand, it needs mechanical repair before anything else. Turning up the force to push through a binding gate wears the opener and makes the gate more dangerous. Let a tech fix the gate and reset the settings.
Questions
Should I turn up the force setting?
Not on your own. Force settings are a safety feature. A gate that needs more force usually has a mechanical problem that should be fixed instead.
Why does it only happen when it’s windy?
Wind pushes against the gate and the opener reads it as an obstruction. A tech can check the opener’s sizing and settings.